Skip to content
cfd-lab:~/en/tools/two-phase-pressure-droponline
$ cd ..

Two-Phase Pressure Drop

Estimate gas-liquid pipe pressure drop with a Lockhart-Martinelli multiplier and a visual phase split.

visual calculatorMultiphase Flow

Read the flow shape before trusting the number.

This page turns a CFD setup into regime, scale, and dominant-effect cues. Adjust the calculator below and compare the moving graphic with the computed result.

01
input scale
02
model
03
check
two-phase flowLockhart-Martinellipressure dropvoid fraction
formula
KaTeX rendered
phi_lˆ2 = 1 + C/X + 1/Xˆ2(dp/dz)_tp = phi_lˆ2 (dp/dz)_l\begin{aligned}\text{phi\_l\^{}2 = 1 + C/X + 1/X\^{}2}\\[0.35em]\text{(dp/dz)\_tp = phi\_l\^{}2 (dp/dz)\_l}\end{aligned}
ASCII sourcephi_l^2 = 1 + C/X + 1/X^2, (dp/dz)_tp = phi_l^2 (dp/dz)_l
Lockhart-Martinelli multiplierliquid film plus gas core
X_LM
0.4763
phi_l^2
47.399
dp/dz 2phi (Pa/m)
4920.35
Delta p total (Pa)
2.460e+4
Re_l / Re_g
1.111e+4 / 8.929e+4

Fast screening model only. Use detailed flow-pattern correlations before final sizing or safety decisions.