Pipe Heat-Transfer Designer

Compute internal-flow Nusselt number, h, and total heat rate with Dittus-Boelter/Gnielinski correlations and a pipe sketch.

q'' wall
visual calculatorHeat Transfer

Read the flow shape before trusting the number.

This page turns a CFD setup into regime, scale, and dominant-effect cues. Adjust the calculator below and compare the moving graphic with the computed result.

01
input scale
02
model
03
check
Nusseltpipe heat transferGnielinskiconvection
formula
KaTeX rendered
Nu_Gn = (f/8)(Re-1000)Pr / [1 + 12.7(f/8)ˆ(1/2)(Prˆ(2/3)-1)]\begin{aligned}\text{Nu\_Gn = (f/8)(Re-1000)Pr / [1 + 12.7(f/8)\^{}(1/2)(Pr\^{}(2/3)-1)]}\end{aligned}
ASCII sourceNu_Gn = (f/8)(Re-1000)Pr / [1 + 12.7(f/8)^(1/2)(Pr^(2/3)-1)]
heated internal flowNu to h to Qbulk flowwall heat flux
Nu Dittus-Boelter
271.36
Nu Gnielinski
308.25
h (W/m2/K)
7644.63
area (m2)
0.236
Q (W)
4.503e+4

turbulent correlation range. Use as a fast CFD wall heat-flux sanity check before committing to a conjugate heat-transfer mesh.