Skip to content
cfd-lab:~/en/tools/lumped-cooling-transientonline
$ cd ..

Lumped Cooling Transient

Compute time constant, current temperature, and cooling curve from thermal capacitance and hA for transient checks.

q'' wall
visual calculatorHeat Transfer

Read the flow shape before trusting the number.

This page turns a CFD setup into regime, scale, and dominant-effect cues. Adjust the calculator below and compare the moving graphic with the computed result.

01
input scale
02
model
03
check
transient heat transferlumped capacitancecoolingBiot
formula
KaTeX rendered
T(t) = T_inf + (T_i - T_inf) exp(-t/tau)tau = rho c_p V/(h A)\begin{aligned}\text{T(t) = T\_inf + (T\_i - T\_inf) exp(-t/tau)}\\[0.35em]\text{tau = rho c\_p V/(h A)}\end{aligned}
ASCII sourceT(t) = T_inf + (T_i - T_inf) exp(-t/tau), tau = rho c_p V/(h A)
lumped transient responsetime
tau (s)
1080.000
T(t) (K)
344.235
Q(t) (W)
221.559
rho cp V (J/K)
4860.000
L_c = V/A (m)
0.01111

Check Biot separately. Lumped cooling is reliable when internal conduction is fast relative to surface convection.