  1. 01

    On a 64-cell Poisson problem, twenty V-cycles drive the residual below 1e-10 while Jacobi, at four sweeps a step, stalls near 1e-2.

    2026.05.06

  2. 02

    Explicit CFL at 0.3 stalls for days. Backward Euler and two LU-SGS sweeps carry a Burgers shock through CFL 5 in 49 steps, with no full-matrix inverse.

    2026.06.22

  3. 03

    On a 40 by 40 Poisson problem, 1600 unknowns reach a residual of 8.74e-11 in 78 matrix-vector products, and the true residual is 9.02e-11.

    2026.06.24

  4. 04

    Fixed CFL of 3 needs 588 iterations on steady Burgers. SER with p=1 finishes in 34, then the step is Newton only while a finite CFL cap is still in place.

    2026.06.29

  5. 05

    Fraysse (2019) seeds dual numbers through an unchanged flux routine and reads a machine-precision Jacobian, with no finite-difference step h to tune.

    2026.07.05

  6. 06

    At M=0.02 the acoustic band stays 2c wide while convection crawls. Feeding R back into the upwind step holds the momentum error at 2.2e-16.

    2026.07.11

  7. 07

    At Mach 10^{-4} the time step stays on the convective CFL. Pure second-order IMEX overshoots by about 0.4 unless theta is held to sqrt(2)-1 or below.

    2026.07.26

  8. 08

    On a 64 by 48 mesh, Jacobi climbs from 18 sweeps at aspect ratio 1 to 5471 at 1000, while a wall-normal linelet finishes in 2.

    2026.07.31

  9. 09

    Shuffling cell numbers on a 576-cell grid pushed LU-SGS from 9 iterations to 25. RCM cuts bandwidth to 24, but the start corner still splits 9 from 21.

    2026.10.16

  10. 10

    Stop Jacobi when the update drops below a tolerance and the error left behind grows as 1/(1-ρ) on finer grids. A 2D heat-conduction plate compares Jacobi, SOR and optimal ω.

    2026.10.21

  11. 11

    In the same implicit Euler step, penalty contact skips over a thin wall while the IPC log barrier with a CCD-filtered line search stops micrometers short. A 1D experiment shows why.

    2026.10.29

  12. 12

    Put a Weiss–Smith preconditioner into physical time and the acoustic pulse freezes in place. Put it inside dual time and the answer returns, but inner iterations jump from 16 to 305.